Arctic Heater Kit Maintenance Instructions (Cont)
21-2. ARCTIC KIT COOLANT PUMP REPAIR fCONT)
(7)
Install puller tool on pump body (12) using four screws (18) removed from pump body (12) in
step (5).
CAUTION
Motor will come off pump body when armature shaft is pressed out of impeller.
NOTE
Two nuts removed in step (6) hold motor together. Keep motor as an assembly.
(8)
(9)
Tighten puller screws on shaft of armature (22) and press shaft out of impeller (23).
Remove four screws (18) and puller tool from pump body (12).
(10)
Remove impeller (23) from pump body (12).
NOTE
Note position of components within seal
assembly to ensure proper assembly.
(11)
Remove four piece seal assembly (24)
from pump body (12).
(12)
Remove two drain plugs (25) from pump
body (12).