TM 9-2320-279-34-3
Hydraulic System Maintenance Instructions (Cont)
20-9. HEAVY DUTY WINCH MANIFOLD REPAIR (M984E1) (CONT).
b. Cleaning/Inspection.
WARNING
(1)
(2)
(3)
(4)
(5)
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
Clean all metal parts in dry cleaning solvent.
Inspect each part for damage.
Replace damaged parts.
Replace small springs if free length is less than .375 in. (9.53 mm) or broken.
Replace large springs if free length is less than 1.250 in (31.75 mm).
c. Assembly.
(2) Install two preformed packings (3) and plugs (4).
(1) Install preformed packing (1) and plug (2).
(3) Install two balls (5), springs (6), preformed packings (7), and plugs (8) in manifold valve (9).
20-32