TM 9-2320-279-34-1
Change 5
6-14.11
Electrical System Maintenance Instructions (Cont)
(14)
Install red wire (25) on positive (+)
rectifier (18) with screw (26).
(15)
Install three terminal studs (27) on
regulator holder (28) with three nuts
(29).
CAUTION
Red and black rectifier wires should be
positioned in grooves between regulator holder
and slip ring end housing. Failure to comply
may result in damaged wiring.
(16)
Install positive (+) terminal screw (30),
negative (--) terminal screw (31), two
insulation bushings (32), regulator
holder (28), new gasket (33), and two
nuts (34) in slip ring end housing (6),
positive (+) rectifier (18), and negative
(--) rectifier (9).
NOTE
·
Rectifier leads should be firmly
seated in regulator holder.
·
Wires should be positioned in
locations marked during removal.
(17)
Install six rectifier leads (35) on three
regulator studs (36).
(18)
Install capacitor (37) on positive
rectifier (18) and negative rectifier (9)
with two screws (38).